YAG Laser
Specular Microscope
Contrast Sensitivity Testing Device
Electroretinogram (ERG)
Laser Flare Meter
Fundus Camera
Optical Coherence Tomography (OCT)
Ultra-widefield Retinal Imaging Device
Angiography Device
Visual Field Analyser
Anterior Segment Ophthalmic OCT Device
Ophthalmologic Ultrasound (A/B Scan)
PASCAL Laser
IPL Laser for Dry Eye Treatment
YAG (Yttrium Aluminum Garnet) Laser is a device that utilizes lower yet efficient energy compared to traditional laser equipment for treatment. It is commonly used for laser treatment, particularly in treating posterior capsule opacification (PCO), which is the most common complication of cataract and glaucoma surgery.
Laser Synechiolysis
PCO after Cataract Surgery
(Laser Capsulotomy / Source:
Wikipedia)
Example of YAG Laser Treatment Process
YAG Laser is set up → Patient’s mydriasis is checked → Anesthetic is instilled into the patient's eyes → Patient is seated and laser treatment is performed
The cornea—which is only about 0.5mm thick on average—is composed of five layers, and among them, the innermost layer called the endothelium is crucial for the overall health of the cornea. Specular Microscope plays a significant role in examining the health of the corneal endothelium, from examinations before and after ICL (implantable contact lens) to examinations for corneal edema.
Healthy endothelial cells in a 30-year-old male are characterized by the following
Contrast Sensitivity Testing Device utilizes precisely controlled sine-wave gratings via a computer to accurately measure visual function. It provides precise information on visual function before and after surgery, serving as a crucial indicator for assessing improved conditions post-surgery.
Electroretinogram (ERG) measures intricate details regarding the condition, progression, and state of the retina by analyzing electrical signals produced by retinal nerve cells when exposed to light. ERG examinations are especially beneficial for evaluating patients prior to cataract surgery and for the diagnosis of retinal conditions or glaucoma. At The One Seoul Eye Clinic, the entire ERG procedure—including preparation and examination—takes about 7 minutes in total, and the electrodes used for the examination are non-intrusive, ensuring optimal comfort for patients
Example of Measurement Results:
Right Eye Normal / Left Eye
Abnormal
Non-invasive Electrodes
Laser Flare Meter is a device that measures the presence and condition of intraocular inflammation (uveitis, keratitis, scleritis, etc.) based on the number of protein clusters within the aqueous humor, reflected and confirmed through the principle of light scattering after projecting a laser into the eye. This equipment is useful for outpatient examinations and follow-ups after cataract surgery.
Front View
Side View
Example of Measurement Results
In a normal eye, an average of 2.9 to 3.9 photons is observed per millisecond. If more than 30 photons are observed per millisecond, it is considered indicative of inflammation.
Fundus Camera is the first truecolor confocal scanner that accurately recreates the true colors of the retina. It is capable of capturing images automatically even with a small pupil, providing high-resolution images of the retina and optic nerve
Macular Degeneration Detected by Fundus Camera
Central Retinal Vein Occlusion Detected by Fundus Camera
Optical Coherence Tomography (OCT) is essential for the diagnosis and treatment of various retinal conditions such as macular degeneration, diabetic macular edema, epiretinal membrane, and macular hole. Through the vascular imaging mode, it enables non-invasive and more precise examination of subtle vascular changes that were not detectable with conventional equipment
Epiretinal Membrane Detected by OCT
Macular Hole Detected by OCT
Glaucoma Detected by OCT
The Ultra-widefield Retinal Imaging Device is an advanced retinal imaging equipment that can capture images of the peripheral retina without dilation. Utilizing the wide-field autofluorescence mode facilitates easy diagnosis and assessment of the progression of macular degeneration. Additionally, the wide-field fluorescein angiography mode allows the diagnosis of vascular changes in the peripheral retina that were previously undetectable with conventional fluorescein angiography
Retinal Detachment Detected by Ultra-widefield Retinal Imaging Device
Diabetic Retinopathy Detected by Ultra-widefield Retinal Imaging Device
Through the autofluorescence mode, the diagnosis and progression of dry macular degeneration can be assessed. Using indocyanine green angiography (ICG), choroidal neovascularization can be identified, and with fluorescein angiography (FAG), retinal neovascularization can be detected.
Macular Degeneration Detected
by
Autofluorescence Mode
Macular Degeneration Detected
by
Indocyanine Green Angiography
Visual Field Analyser is a device used to examine narrow-angle glaucoma, utilizing the built-in software of the analyzer to automatically diagnose the progression of glaucoma.
Visual Field Test Results of
a Glaucoma
Patient
Screen displaying automatic diagnosis results regarding
the progression of glaucoma using the built-in
software of
the analyzer
(GPA, Glaucoma Progression Analysis)
Anterior Segment Ophthalmic OCT Device is a versatile equipment used for various purposes, including measuring axial length and calculating intraocular lens power during cataract surgery, as well as capturing images of the anterior segment for glaucoma screening. Previously, separate tests such as corneal topography, ocular biometry, and gonioscopy were required, but with this device, one can obtain high-precision images and comprehensive measurements in a single examination, significantly reducing the need for multiple tests.
Corneal Topography Test Results of a Keratoconus Patient
Imaging Results Capturing the Narrowed Anterior Segment Due to Progressing Cataracts
Ophthalmologic Ultrasound (A/B Scan) is essential equipment used to determine the presence and degree of retinal detachment when it is difficult to observe through fundus examination, and to diagnose or differentiate tumors.
Retinal Detachment Detected by Ultrasound
Choroidal Tumor Detected by Ultrasound
PASCAL Laser features enhanced functionality compared to traditional lasers, providing less pain during treatment and significantly reducing treatment time. It is commonly used for laser treatments in conditions such as retinal break, diabetic retinopathy, and glaucoma
Screen displaying selectable laser patterns
according to the situation to reduce treatment time
Performing Panretinal Photocoagulation
(PRP)
with PASCAL Laser
IPL (Intense Pulsed Light) laser is used to treat dry eye syndrome caused by meibomian gland dysfunction, which are oil glands along the rims of the eyelid inside the tarsal plate. The equipment irradiates the IPL laser to destroy abnormal blood vessels and heat to melt and open clogged meibomian glands
Put on eye protection shield → Apply gel to the treatment area → Irradiate M22 IPL laser (approximately 5 minutes) → Remove gel and cool & soothe if necessary (5 minutes)
Inflamed and Hardened Oil Glands Before IPL Treatment
Clear Oil Glands After IPL Treatment